Showing posts with label certification. Show all posts
Showing posts with label certification. Show all posts

Friday, March 31, 2023

Reflections on the EPA Inspector General’s residential wood heat report

    The Environmental Protection Agency’s (EPA’s) internal watchdog, the Office of Inspector General (OIG) concluded that the agency does not have an effective program to test and certify wood stoves.  Much of the OIG's report tracks findings and positions of an earlier report by North East States for Coordinated Air Use Management (NESCAUM), which triggered the OIG report (NESCAUM 2021). But the OIG report has a level of authority over the agency and provides a roadmap for much needed changes.

    The OIG report finds extensive faults with the Office of Air and Radiation (OAR) and Office of Enforcement and Compliance Assurance (OECA) instead of laying blame with EPA leadership which for decades under both parties has failed to provide those offices with the resources and expertise they need to effectively do their job. Successive administrations have undervalued the vital role that wood and pellet stoves play, particularly for the rural poor, and also underappreciated the enormous levels of PM2.5 created by wood stoves. The United States has also failed to develop policies and invest in research and development (R&D) in this renewable energy technology that could be far cleaner.  


    The OIG did not break much new ground and wood heating insiders will not find much new.  Unfortunately, the OIG report also missed some of the same perspectives that NESCAUM missed, providing a one-sided view of many problems. Overall, the Alliance for Green Heat (AGH) agrees with most of the findings and the recommendations but is very concerned that the OIG, like the offices within the EPA that it criticized, may not have had the expertise to understand broader issues, other than ones raised by NESCAUM.  


    Both the NESCAUM and the OIG report consistently and incorrectly referred to “wood heaters” when they should have used the term “wood stoves.” Wood heaters include pellet stoves, a mainstream stove technology used by hundreds of thousands of consumers which do not share most of the problems wood stoves have and are a good alternative to wood stoves. The OIG failed to reassure consumers that pellet stoves can offer a cleaner and more trustworthy option. 


    Like the NESCAUM report, the OIG also failed to consider that the original test methods dating from 1988 may also be flawed and may not produce stoves that meet the PM2.5 emission standards.  We suspect that independent retesting of stoves using both test methods – Method 28  and ASTM E3053 - would find stoves emitting far more than the allowable emission levels.  


    The OIG’s quotable finding that consumers can still purchase stoves that failed EPA tests may gain far more traction with the media and environmental groups than it deserves. There is little evidence that those particular stove models are more susceptible to higher emissions than other models. Moreover, the dryness of the wood put into a stove and the amount of air the consumer gives the stove have an exponentially greater impact on emissions than which test method was used to certify the stove.  


    We do not agree with the assessment that EPA's funding for change-out programs should be questioned based on the NESCAUM or the OIG report. The managers of many of these change-out programs likely have far more expertise than the authors of the OIG and know all too well that changing out an old wood stove for a new one has limitations.  Many funds also go to bounty programs, education, pellet stoves, hybrid stoves and increasingly to heat pumps, not just new non-cat wood stoves.


    To get a broader perspective on these issues, we highly recommend reading an article about the experience of one manufacturer and their experience dealing with the EPA certification process as it rushed to respond and fix its system.


    Like the NESCAUM report, the OIG report did not consider the obvious option for the EPA to amend and improve E305, rather than revoking it. Neither report assessed the bigger picture of how ASTM E3053 could have been part of the effort to develop a federal cordwood test method by halting its use for 6 – 12 months, amending it and then gathering more data from it during certification testing. As a result, we have lost many years of manufacturers redesigning stoves that can better burn cordwood, instead of continuing to build stoves that burn cribs.


    Both reports are a badly needed wake-up call for the EPA which has neglected a program that deserved far more funding for decades, and our air quality has paid a price. As fossil fuel prices climb, wood heaters are getting more popular and sales have increased dramatically in recent years. Many policies and strategies are needed to reform and guide this renewable energy pathway beyond the deficiencies of the EPA’s certification program. It’s important for all stakeholders to look at the bigger picture and not be constricted by the narrative that emerged from the NESCAUM report.


    One line in the OIG report elicited ridicule from the wood heating community.  It said, “regulators and the public do not have reasonable assurance that certified wood heaters meet emission standards under real-world conditions,” (OIG 2023, 19). We can only assume that the authors of the OIG report knew that EPA emission standards were never meant to mimic real-world conditions and regulators know that all too well. For many in the wood stove industry, this statement undercut the credibility of the report.


    One weakness in the OIG report is its perfunctory treatment of the connection between Wood Smoke and Environmental Justice (EJ). The OIG did not refer to the findings in the 2015 New Source Performance Standards (NSPS), that “risks due to residential wood smoke emissions for disadvantaged population groups generally are lower than the risks for the general population due to residential wood smoke emissions,” (EPA 2010, 9). The 2015 NSPS predated the level of attention that the EPA is now supposed to give to EJ issues, but still EPA has never treated wood smoke as a serious EJ issue. The EPA relied on a very narrow 2010 study commissioned by the EPA’s Gil Wood that did not find increased cancer rate in census data that tracks with higher rates of wood smoke. A finding that wood smoke did disproportionately impact disadvantaged groups would have triggered a requirement that the EPA would have to spend resources to further study this issue. The NSPS discussed the potential causal relationship between wood smoke and cancer numerous times, but when it came to disadvantaged groups, the 2015 NSPS said:


“This proposed rule [2015 NSPS] is not subject to Executive Order 13045 (62 FR 19885, April

23, 1997) because the agency does not believe the environmental health risks or safety risks addressed by this action present a disproportionate risk to children. The report, “Analysis of Exposure to Residential Wood Combustion Emissions for Different Socio-Economic Groups,” shows that on a nationwide basis, cancer risks due to residential wood smoke emissions among disadvantaged population groups generally are lower than the risks for the general population due to residential wood smoke emissions,” (NSPS 2015, 13700). 


    AGH believes this statement is not sufficiently supported by data and reflects the interests of an NSPS process that lacked the funding and leadership to address the EJ issues that wood smoke presents for rural impoverished and marginalized communities. The OIG report did little to change this trajectory. AGH, tribes and firewood banks are urging the EPA to use EJ funds to help wood heating communities.


AGH perspectives on some of the findings of the OIG report.  Sentences in quotes are from the OIG report, followed by AGH’s commentary.


“The EPA Does Not Have an Effective Program for Testing and Certifying Wood Heaters,” (OIG 2023, 13).   

    AGH largely agrees with this basic conclusion that underlies the OIG report. Despite all the shortcomings of the EPA, which were only made widely public by NESCAUM and the Alaska Department of Environmental Conservation (ADEC), it's important to also remember that the EPA program is likely the best certification and testing program in the world for cord wood stoves, and it has pushed manufacturers to build stoves that are cleaner than anywhere else in the world. Testing of solid fuel heaters is inherently extremely complex, rendering programs to regulate them vulnerable.  


“The 2015 NSPS and Certification Test Methods Are Flawed,” (OIG 2023, 13). 

    AGH agrees that the 2015 NSPS is flawed but we should not forget some of its most important and most successful results. It finally made outdoor boilers a fully regulated appliance, and ended the loophole of allowing many wood and pellet stoves to be “exempt.” It also jump started a new category of stoves: hybrid stoves that use both catalytic and non-catalytic smoke reduction technologies. However, the operational benefits of hybrid stoves have been overlooked by ADEC and NESCAUM, contributing to California Air Resources Board (CARB) focusing on catalytic stoves in their change-out programs instead of hybrid stoves, which continue to reduce PM even if the cat is not engaged or its clogged or missing.  OECA has also made many improvements to its database of certified wood heaters. The database used to be maintained on excel spreadsheets and lacked much of the detail that it now has. We hope it will be further populated with relevant info, including the expiration date of each stove’s certificate in ways that will not confuse consumers. The EPA program is effective and credible in many ways, despite the deep flaws identified in the OIG’s report. 


  • The 1988 NSPS was far more flawed than the 2015 NSPS and for 20 years the EPA largely ignored those flaws, as did state agencies.  

  • ALT-125 and ALT-127 (ASTM E3053) could have been improved, instead of revoked.  

  • “Testing labs can conduct test runs to produce data that misrepresent wood heater performance to regulators and consumers,” (OIG 2023, 14). This has always been the case and is not a product of the 2015 NSPS.


“The Wood Heater Certificate-of-Compliance Process Lacks Internal Controls,”(OIG 2023, 19). 

    AGH agrees with this conclusion and OECA’s estimate of $100,000 to continue detailed review of certification papers is a small sum given the improvements needed. We question whether the use of contractors is the best way forward for OECA, rather than building its own internal capacity and expertise.   

  • “The Agency Does Not Exercise Its Authority to Observe Certification Testing,” (OIG 2023, 21). This activity is yet another victim of underfunding. We believe both OECA and the Office of Air Quality Planning and Standards (OAQPS) staff should regularly observe certification testing as a primary strategy to build its expertise. 

  • “The EPA Does Not Use Its Regulatory Authority to Conduct Compliance Audit Tests,” (OIG 2023, 21). We urge the EPA to begin compliance audit testing, primarily of the most popular models to start with


OIG RECOMMENDATIONS

  • “Develop and implement a plan to demonstrate whether residential wood heaters certified using the test methods based on ASTM E3053 comply with the New Source Performance Standards for residential wood heaters,” (OIG 2023, 26). This is a nonsensical recommendation unless similar tests are done on stoves tested with Method 28. The EPA should approach all test methods without bias and develop scientific ways to assess all test methods.  

  • “Develop and adopt an EPA cord wood test method that is supported by data to provide the public reasonable assurance that certified appliances meet emission standards,” (OIG 2023, 26). Emission numbers in labs will never be the same as emissions in the hands of consumers, particularly if manually operated stoves continue as the dominant technology in North America.  Automated stoves and controls like ESPs are likely the leading options to reduce the gap between lab and field emission profiles. 

  • “Establish mechanisms to promote independence between emissions testing labs and third-party certifiers,” (OIG 2023, 26). AGH is not convinced that the next NSPS should extend the role of third-party certifiers. While it may have been a good idea, it didn’t work and other strategies should be considered before trying to fix this process.



Response of the EPA


    We believe that it's important to also read the response by the EPA to the OIG which was included in the end of the report.  We felt their response was fair and measured, and acknowledged many of the charges in the OIG report. However, the EPA also pushed back in many areas, such as this: “The OIG draft report improperly conveys that EPA has generally not altered how we are implementing the wood heater program,”(OIG 2023, 30). We fully agree with this statement because the EPA began improving their program even before the NESCAUM report came out, and accelerated their pace afterwards.  


Conclusion

    AGH believes the work of ADEC, NESCAUM and the EPA’s OIG is generally having a positive impact.  While there have been many missteps and miscommunication, and sometimes an inordinate burden on manufacturers, this process finally got the attention of the EPA leadership and more resources to the EPA offices working on these important issues. It is still unclear if the EPA leadership will continue to give more priority and more resources to this area in coming years and under different administrations.


    States also have a responsibility to put more resources into this area and develop their expertise, if they want to see continued change at the federal level. States can do a lot, as Washington and Oregon have demonstrated by banning the installation of uncertified stove. Cities can restrict the installation of any wood stove and other solutions are emerging in Europe such as requiring electrostatic precipitators, whose prices are dropping rapidly. The Department of Energy (DOE), their national labs and universities can also play a vital role by supporting more R&D and pushing for the development of automated, computer generated stoves, something the EPA has paid little attention to.


    Wood and pellet stoves are not going away and provide a vital source of renewable heat to more than 10 million American homes. They have successfully helped America decarbonize residential heating far more than they get credit for. With increased R&D, innovation and regulatory oversight, wood and pellet heat can continue to help us achieve carbon reductions that are badly needed to stave off the worst impacts of global climate change. A key part of this process lies with the EPA by addressing many of the issues raised in the OIG report.


Wednesday, October 27, 2021

Inspector General investigating EPA’s oversight of its residential wood heater program

On October 22, 2021, the EPA’s Office of the Inspector General announced it was launching an investigation into the EPA’s residential wood heater testing and certification program. The memo announcing the investigation was directed at both the Office of Enforcement and Compliance (OECA) based in DC and the Office of Air and Radiation (OAR) whose staff is mainly based in Triangle Park, North Carolina. The report is scheduled to be published sometime next year.

The Office of the Inspector General is “an independent office within the EPA that helps the agency protect the environment in a more efficient and cost-effective manner.” It identifies areas it believes need investigation and issues a public report with recommendations. While it does not have enforcement power, the EPA is expected to take the Office's recommendations seriously. There can be disagreements over priorities and that is already happening in the water program and elsewhere. The OIG also submits semiannual reports to Congress. In the event that the EPA ignores any of the recommendations made by OIG, it is possible that the agency can be pressured to address them through hearings, appropriations riders or funding. The EPA OIG can also uncover criminal behavior, which would be addressed accordingly by the U.S. Attorney's Office.

 

More specifically, the memo announcing this evaluation says, “Our objective is to determine whether EPA effectively uses its oversight and enforcement authority to ensure that all residential wood heaters reaching consumers are properly tested and certified in accordance with established standards. … We may also choose to include a sample of regions in our evaluation and to conduct work at laboratories and third-party certifiers in selected regions.”

A current ad for uncertified
outdoor wood boilers

Before publicly announcing this evaluation, the OIG contacted the Alliance for Green Heat on Oct. 13, 2021 and held a conference call with AGH on Oct. 21. For years, AGH has been raising alarm bells about the lack of EPA enforcement in a number of areas, including the numerous companies that continue to manufacturer and sell outdoor wood boilers. AGH has often contacted the EPA Office of Enforcement and published stories on our newsletter on companies who make and/or distribute uncertified residential central wood heaters, including ACME (Missouri), EZBoiler (Michigan), Hyprotherm (Arkansas) and MBTEK (Pennsylvania distributor of Polish appliances). AGH has spoken with most of the companies by phone and they say that they have never been contacted by the EPA or a state agency about certification issues.

AGH also raised EPA’s failure to contact the whistleblower regarding the credible allegations of fraud at US Stove Company, along with a number of other areas where enforcement action was needed.

The OIG’s evaluation is also believed to have been triggered by the NESCAUM report, Assessment of EPA’s Residential Wood Heater Certification Program, that found a “systemic failure of the entire certification process, including EPA’s oversight and enforcement of its requirements.” That report led the EPA to conduct its own review of the certification paperwork for all certified stoves. The EPA is contacting scores of companies to obtain missing information or for clarification. In some cases, it is requiring the company to have the stove tested again.

If you have evidence of misconduct or mismanagement regarding the EPA’s oversight of wood heater testing or certification, you can provide information using this form, and refer to case OSRE-FY22-0026.

Further reading:

Tuesday, April 6, 2021

EPA announces extraordinary overhaul of wood stove certification program

Confidence in wood stove testing program shaken in wake of Alaska and NESCAUM exposé

Richard Wayland leads the nation’s
technical air quality management
programs


On Tuesday, April 5, the EPA published letters that they sent to wood stove testing labs, announcing they were embarking on a historic review of certification paperwork, similar to the examination that the state of Alaska is conducting.

 

The publication of the letters may have been prompted by a freedom of information request from a reporter, who got access to the letters hours before the EPA published them.

 

The overhaul could end up costing stove manufacturers large sums of money and the revocation of some models' certification.  This is sending reverberations throughout the manufacturing community of wood and pellet heating appliances, which has never faced such scrutiny and oversight since wood stoves were first required to be certified in 1988.

 

The EPA announcement is also derailing, at least temporarily, a move by members of Congress to refile legislation that would establish a national wood stove change out program heralded by industry as the best way to combat excessive wood smoke.  The EPA emphasized that local and state change out programs rely on EPA certification documents to help determine which stoves can achieve the best emission reductions. 

 

The immediate actions by the EPA include using a template similar to the one used by the state of Alaska to see if their review of deficiencies in paperwork matches the the state's review.  This indicates, as early reports confirm, that the EPA may not agree with some of the categories of deficiencies Alaska thought were significant.

 

The EPA is also announcing that starting immediately, they will be conducting far more intensive reviews of new certifications.  This is believed to also include the routine retesting waivers.  Under the current system, once a stove gets certified, it receives a 5-year certificate that can be renewed, without any additional testing, over and over.  While this benefits manufacturers who, prior to 2015, were still marketing stoves certified in the 1990s, it did not incentivize making even small improvements in the cleanliness or efficiency of the unit every 5 years.  

 

The letters to the EPA approved stove testing labs also put the labs under notice that they could lose their approved status if they do not improve their standard operating procedures. It is unclear why half of EPA approved labs and third-party certifiers appear to have expired approvals.  The newest third-party certifier, Guardian Fire Testing Laboratories, is based in New York, the state that has been providing most of the funding to NESCAUM through its energy department, NYSERDA.

List of EPA approved labs and 3rd
party certifiers who received letters

 

Although the letters the EPA sent to wood stove test labs dealt mostly with enforcement issues, they did not come from the EPA's Office of Enforcement, but rather from Richard Wayland, the Director of the Air Quality Assessment Division, which typically does not handle such measures.  Wayland’s Division is now under a new high profile political appointee, Joseph Goffman, who was one of Biden's top advisors during the presidential transition.  Under Goffman is Tomas Carbonell, the Deputy Assistant Administrator for Stationary Sources, another political appointee who worked on the 2015 wood heater NSPS during his tenure at the Environmental Defense Fund.  This may indicate a shifting and larger role for senior leadership at the Office of Air and Radiation, a potential sign that the Biden Administration is taking the NESCAUM report very seriously.

 

The EPA stopped short of implementing some of the recommendations in the NESCAUM report.  For instance, they have not yet indicated any interest in revoking an ASTM cordwood test method that NESCAUM and Alaska found to be flawed.  However, the agency did emphasize that the recently approved IDC cordwood test method could be used by any manufacturer and updated their approval of the method, possibly to correct an error found by veteran stove tester Ben Myren.  That error, which the Alliance for Green Heat highlighted in a recent blog, dealt with the amount of bark that must be left on logs during certification testing, and highlights the precarious role of the EPA in approving test methods where the underlying data has not been publicly released for experts to review.  It is unclear if EPA even had access to the IDC test method's underlying data which is owned by NYSERDA.  If the agency does have the data, it could make it available or it may have to disclose it through freedom of information requests.  


The EPA's announcement of this major overhaul comes just days after many top stove manufacturers and the main industry association, the Hearth, Patio & Barbecue Association,  filed comments vigorously opposing the results of the Alaska stove certification review. If the EPA does not approve Alaska's scheme of culling out stoves with too many deficiencies in their paperwork and which emit more than 6 grams an out during test runs, Alaska may be forced to only allow the new installation of pellet appliances in the Fairbanks area, that is fighting federal non-attainment status.


For many years, experts have known of the mounting complexities and loopholes in testing wood stoves. Then, by 2020, it became apparent that many stoves that were tested above 2 grams an hour were somehow able to test to below 2 grams an hour without being altered, calling into question whether the regulations led to a cleaner generation of wood stoves.  Pellet stoves and boilers however have genuinely become cleaner and more efficient from the tighter 2020 emission standards because of their automated functions and consistent fuel qualities. 


Related stories

EPA's cordwood test protocol moves forward (July 2021)

EPA and states vigorously defend stove audits (Sept. 2020)

Opinions of top stove industry insiders on controversial topics (Aug. 2017)

Study shows environmental advantages of pellet stoves and exaggerations by manufacturers (Oct. 2015)




 

Wednesday, February 20, 2019

Non-cats cleaner than catalytic or pellet stoves in new certifications

In the most recent updated list of EPA certified stoves, 17 more units became 2020 compliant, meeting the 2020 EPA regulations of emitting no more than 2 grams an hour.  While it is not a large sample size, among this batch of newly certified units,  the non-catalytic stoves averaged 1.2 grams an hour, whereas catalytic stove averaged 1.3 and pellet stoves averaged 1.4.  It is not yet clear if the non-catalytic stove designers used new innovative technology or just fine-tuned existing strategies to reduce particulate matter.
Of the 17 newly certified stoves,
non-catalytic models are the cleanest

Many industry experts have argued that the 2020 emission standard of 2 grams an hour favors catalytic and pellet stoves.  But we are seeing some non-cats come in below 1 gram an hour, including 2 of the 5 in this recently certified batch.  Many of the 2020 compliant non-cats do fall in the 1.5 to 2 gram range.  And every once in a while, a stove goes into the lab and doesn't quite meet the 2.0 gram standard, like a IHP stove that recently came out certified at 2.1 grams.  Assuming this unit was not tested with cordwood (which are allowed up to 2.5 grams per hour), this means that the model can only remain on the market in the US for less than 18 months until May 2020, unless the EPA were to approve a sell-through.

Efficiency

The average efficiencies show a less surprising trend: the 13 newly certified non-catalytic and pellet stoves had the same average efficiency – 69%.  The four catalytic stoves, including one hybrid, had an average of 77% efficiency.  These efficiency numbers are typical of averages of all stoves on the market. Pellet stoves have long had the reputation of being a more efficient technology, but over the last several years, as manufacturers were required to disclose efficiencies,  we saw that pellet stoves had a far greater range on the low and high end, with the average being about the same as non-cats.  Even among this small sample, pellet stoves had the lowest efficiency unit (at 60%) made by Sherwood Industries.  Sherwood also made the highest efficiency pellet stove in this newly certified batch – at 77%.

Efficiency could be a more important metric if Congress re-instates the tax credit for residential wood heaters.  That credit was worth $300 but expired in December 2017.  Stoves needed to be 75% efficient to qualify for the tax credit, but manufacturers were allowed to claim eligibility without disclosing their real efficiency, allowing virtually all stoves to qualify.  The practice of exaggerating efficiencies and misleading consumers got to the point that even the industry association, the Hearth Patio & Barbecue Association, changed course in 2018 and recommended that only publicly disclosed efficiencies on the EPA list of stoves be used in the future to determine eligibility.  If the credit is reinstated, there is a chance that the eligibility number could be reduced to 73%, in part to help more non-catalytic stoves qualify.

Carbon monoxide

The other metric that test labs are now required to report is carbon monoxide, another very important test of cleanliness, along with particulate matter.  By far the cleanest technology in terms of CO is the pellet stove. The pellet stoves in this small batch had an average of 0.42. grams an hour of CO, the catalytic had 0.63 grams and non-catalytic stoves had 1.2 grams – almost double the CO of non-cats and triple that of pellet stoves.

A stove's ability to burn off carbon monoxide often tracks its ability to burn off particulate matter.  Of the pellet stoves, the three with the lowest CO also had a lower average PM (1.2 grams an hour), and the three with higher CO had a higher average PM (1.5 grams an hour).  

Overall progress towards 2020

There are 533 stove models on the latest list of EPA certified stoves that are currently in production.  Many of those units will never be changed to become 2020 compliant and many are already not being produced any more.  Industry experts say that the number of stove models will contract as we get closer to 2020, likely in the range of 300 – 400 models.  As of February 2019, 119 models are 2020 compliant.  (The number of 2020 compliant models is consistently under-reported due to delays in processing and notification.)  Many manufacturers may also have completed their R&D and/or their testing but have not submitted the data to the EPA. 

Most stove manufacturers have at least a third to half of their models 2020 certified – including larger brands such as American Energy Systems, Blaze King, Even Temp, Fireplace Products International, Hearthstone, Pacific Energy, Rais, Ravelli, RSF/ICC, Sherwood Industries, Stuv, Travis and Woodstock Soapstone.

However, the two largest value stove manufacturers in the US market – US Stove and Englander – only have pellet stoves certified and still do not have any 2020 compliant wood stoves.   They sell to big box stores, which buy even earlier than specialty retailers.  It is still too early to tell if big box stores will replace Englander and US Stove models with models from other manufacturers, likely at higher prices.  Some in industry hope that the 2020 emission standards will help specialty heath stores regain some of the market share they had lost to the big box stores over the past decade.  

Tuesday, July 15, 2014

EPA bolsters legal case for NSPS with new data

Alliance for Green Heat, July 15, 2014 - On July 1st, the EPA released a NODA – a Notice of Data Availability – consisting of data from 3 stoves tested with cordwood and 106 stoves tested with crib wood. 

Vermont Castings combustion engineer
Doug Fongeallaz uses cord wood to test
a stove instead of  Doug fir cribwood,
according to the Valley News.
The NODA is a vehicle for letting people know the EPA is relying on this evidence to make their final rule, so parties won’t be able to say that the agency surprised them, in violation of procedure for issuing new rules, if the EPA cites it.  The NODA also provides stakeholders a chance to dispute the additional evidence since it was not available at the time the rule was proposed.  The fact that EPA has published this data and the NODA in the federal register now allows EPA to rely on this data for the final rule.  It is likely that HPBA will publicly respond and a number of manufacturers and agencies are also planning on responding.

This NODA lays a better legal basis to withstand a potential lawsuit from the hearth industry and also gives more insight into what final emission standard the EPA is able to set.  Many in industry claim that the EPA does not have sufficient data to set an emission standard based on cordwood.  And some manufacturers have data but are not sharing it with the EPA in an attempt to prevent the EPA from establishing a cordwood emission standard.

Overview

This new cordwood data shows that some catalytic stoves can already meet a 1.3 grams per hour standard with cordwood.  However, the non-catalytic stove performed far worse with cordwood than it did with crib wood, with grams per hour of 4.2 on the Category IV burn, 11.7 on Category III and a whopping 39.9 on Category II.  The stove was not able to burn at Category I, the lowest air setting, either with cordwood or in the crib wood certification test.  Among the 63 non-cat stove tests released by the EPA in the NODA, only 8 of them could be tested at Category 1, the low burn rate.  It is is unclear how many of these 63 stoves can be operated by the consumer at a lower burn rate than they were tested at in the lab. The HPBA campaign to raise the minimum burn rate from 1 kg/h to 1.15 kg/h could have significantly added to the problem of stoves not being tested the way consumers often use them.

The data partially confirms what industry has been arguing – that it's still too early to set a cordwood standard for non-cats.  Firstly, there is too little publicly available data, and, even if the standard remained at 4.5 grams per hour (but with cordwood), manufacturers may not be able to make non-cat stoves that qualify. The incredibly high emissions from this non-cat stove could be a factor in leading the EPA to postpone a cordwood certification standard.  Presumably the EPA would require cordwood testing over the next 8 years and possibly make cordwood certification optional, while continuing to rely on crib certification.

The data also partially confirms what many air agencies have been saying: that some stoves can readily meet a 1.3 grams per hour standard, which is all that is legally required by the EPA to meet the best available technology test.

At the core of this issue may be the decision by EPA, not contested by HPBA, to set a single standard for cat, non-cat and pellet stoves.  There is data to show that pellet and cat stoves can meet a 1.3 standard now, but without separating them, the non-cat stoves may delay reaping the low-emission benefits of those technologies. Some manufacturers, such as Jotul, initially argued that cat and non-cat standards should be delinked, but others were against delinking, including the Catalytic Hearth Coalition.  The Alliance for Green Heat and a few others argued for a separate category for pellet stoves.  The internal politics and public rift within HPBA over this issue contributed to the industry association remaining silent on the issue of single or separate standards for cat and non-cat stoves.  Only time will tell if this is a successful legal strategy.

An attorney who specializes in NSPS law and is familiar with this case says that "the EPA could, in theory, set a legally defensible emission limit for both cat and non-cat stoves that relies on emission rates that are achievable by catalytic stoves but that may not be achievable by non-cats. EPA can’t require a specific technology under section 111, but it has the discretion to set the emission standard at a level that has only been achieved by one type of technology.  I suspect EPA would probably win on this point if challenged, however at this early stage, such predictions are still very speculative.  Ideally, there will be more data points than just 2 stoves, but I don’t think that’s going to be fatal to EPA, especially if industry isn’t willing or able to produce cordwood test data contradicting EPA’s data."


(The Alliance for Green Heat does not support a cordwood standard such as 1.3 grams per hour that some cat stoves appear to be able to meet, but regularly consults legal experts to see what EPA can do.  The danger may be that regardless of the recommendations from the EPA's stove experts based in North Carolina, far more senior EPA officials in Washington may take a much harder line.)

Summary of Woodstock Soapstone stove

Tom Morrissey, back row, 2d from
right and the team that built the
Ideal Steel Hybrid that emits less
than 1.3 grams an hour with
cordwood and cribs.
Woodstock Soapstone voluntarily provided full cord and crib wood test results to the EPA, something that perhaps no other stove manufacturer did during the NSPS process.  Woodstock Soapstone is one of the few stove manufacturers that is not a member of HPBA and thus does not follow their advice and guidance on sharing information with the EPA and what positions to take on contentious NSPS issues.

Woodstock Soapstone's stove showed a very notable consistency in emissions of grams per hour between cord and crib wood.  Certification tests using crib wood produced between 0.3 and 1.3 grams per hour for the four burn rates.  R&D testing in the manufacturer's lab with crib wood produced 0.4 and 0.5 grams per hour and between 0.5 and 0.8 grams using cordwood. 

Similarly, the stove showed high levels of consistency in efficiency between cord and crib wood and the certification lab and the manufacturer’s lab. Crib tests were between 74 and 84.5% efficiency HHV, and between 74.2 and 82.3% for cordwood for all the burn rates.

Summary of catalytic stove #2

A second, unidentified manufacturer voluntarily provided test results for 2 catalytic stoves.  A summary note from Gil Wood said, “the test data show that these two EPA-certified catalytic wood stoves when tested using cordwood - and making no design changes to adjust for crib wood versus cordwood in the tests - have similar emissions as when they were tested for the official EPA certification tests using crib wood. That is, the test data show particulate emission rates (g/hr) using cord wood that are equal to or less than the corresponding test data using crib wood for Category 1 (minimum burn rate) and Category 4 (maximum burn rate).”

The stove produced between 0.3 and 0.8 grams per hour for cord wood for Category I and IV.  A second Category IV test came in at 0.8 as well.

Summary of non-cat stove

A popular non-cat stove was purchased for testing at Brookhaven National Lab that was under contract with EPA to test cordwood in non-cats.  According to the Brookhaven test report, “the test cord wood was guided by draft cord wood specifications and procedures under active development by ASTM.  Testing was successfully completed in Method 28 Categories IV, III, and II.  It was not found possible to achieve the Cat. I burn rate with this fuel when the air control damper was fully closed. In this case Method 28 provides a method for determining average emissions based on weighting the results of the other three categories in which the stove was tested. It should be noted that in the earlier certification testing with crib wood, Category I operation was also not achieved.”

One notable result is that this popular non-cat had three very reproducible emission rates over a 3-day period.  On Cat IV, the stove produced 4.2 grams per hour on May 19th, 4.1 on May 20th and 4.3 on May 21th for an average of 4.2.  Reproducibility fell apart on Category III, with burns over 5 days producing a range from 6.4 to 17.4 grams an hour, for an average of 11.7.  Category II had slightly better reproducibility when the stove was smoldering at very high rates of particulate matter.  It produced 36-48 grams per hour over 4 days for an average of 39 grams per hour.  The high emission rates may partially be the result of fuel where the core moisture content was sometimes above 30%, although an average of core and shell was always below 25%.

The stove was also tested with very high moisture content fuel of 48.4% moisture content on a wet basis. Brookhaven found that particulate emissions were extremely high: 50.6 g/hr over the run, and 11.8 times higher than the average emission rate with the drier test fuel in Category IV.

The Brookhaven report concluded: “For optimal performance of this stove on cord wood, some rebalancing of the primary air / secondary air ratio may be required. It is possible as well that the details of the air damper setting and the procedure for loading and the timing of the startup operations contributed to differences between cord wood and reported crib data.”

Summary of 106 stoves certified by EPA since 2009

The data on the 106 stoves released in this NODA consisted of EPA approved lab certification test reports conducted since 2009.  None of them contained any data about cord wood, but this data set may be extremely important if the EPA decides to continue using cribwood to certify wood stoves in the 2015 NSPS.  Analysis of this data set could form the basis of Step 2 emission standard that is considerably below 4.5 grams per hour.  Some experts expect that the EPA may ultimately designate a standard between 2.0-2.5 grams per hour that would likely take effect in 2020. 

This data set also contained efficiency numbers that had not been reported anywhere before.  A great majority of these stoves are presumably still on the market.  The average HHV efficiency for non-cats and pellet stoves were exactly the same: 71%. Cat stoves had an average efficiency of 79%, but the sample size of 3 stoves was very small.  This data set confirmed previous data sets, that the efficiency range of pellet stoves is far wider than wood stoves.  These certified pellet stoves ranged from 62 to 80% efficient with a standard deviation of 8.5, double the standard deviation of non-cats and four times the deviation of cat stoves.  Some pellet stoves on the market have efficiencies as low as 40% and are likely to be uncertified models. The Alliance for Green Heat will be releasing a separate analysis of these 106 stoves that also shows the correlation between efficiency and emissions.

The EPA is soliciting comments on this NODA before July 31. To comment, click here.

Click here for a related story summarizing comments to the EPA about the proposed regulations.